Multi-purpose low voltage grounding 448
448 / Anbaco - Vietnam
- Includes 4 alloy ground clamps
- The clamp head uses a wire clamp with a contact area of ​​50 ~ 300mm², the nose side can be made into a V shape up to 120⁰
- Ground wire made from 16mm² / 25mm² copper wire covered with 1mm PVC
- Set includes 1 piece of wire 1.5m long and 3 pieces 0.4m long connected by an insulated clamp (can be lengthened upon request)
- Used for grounding before performing work on 3-phase low voltage lines, Aptomat output at nuts and cables.
- Industrial design patent No. 21256 issued by the National Intellectual Property Office.
0 ₫ 0.0 VND
Medium voltage mobile grounding 3351
TD - 3351 / Anbaco
- Clamp head made of aluminum alloy
- The hot line clamp has a good spring and is tightened with a threaded ring. The contact surface between the clamp and the wire is large, good and even.
- The clamp head can clamp wires with a cross section of up to 240mm².
- There are 4 clamps for 01 set of ground wires.
- Grounding wire: Multi-strand soft copper wire with clear PVC coating; Uncoated wire cross section is 16mm²/25mm², PVC coating thickness is 1mm.
- There are 4 pieces of wire, each 2m long (or longer as required).
- At each end of the wire attached to the clamp head and the middle point connecting the wire segments, there must be a pressed coss. - At the pressed coss positions, there must be a flexible rubber cover on the outside to prevent the wire from fraying or breaking due to use. long time.
- Used to ground the medium voltage grid with voltage up to 35kV before performing work
0 ₫ 0.0 VND
VICADI low voltage insulating mat (1m x 0.65m)
TCD3KV-0.65x1 / Vicadi - Vietnam*
- Material: 100% insulating natural rubber
- Color: Red brown
- Dimensions: 0.65m x 1m x 5mm thick
- Voltage used: 3,000V AC
- Test voltage: 20,000V AC / 1 minute
- Leakage current ≤ 20 mA
- Each product comes with a factory inspection card
0 ₫ 0.0 VND
VICADI low voltage insulating mat (1m x 1m)
TCD3KV-1x1 / Vicadi - Vietnam*
- Material: 100% insulating natural rubber
- Color: Red brown
- Dimensions: 1m x 1m x 5mm thick
- Voltage used: 3,000V AC
- Test voltage: 20,000V AC / 1 minute
- Leakage current ≤ 20 mA
- Each product comes with a factory inspection card
0 ₫ 0.0 VND
VICADI 35 kV insulating mat (1m x 1m)
TCD35KV-1x1 / Vicadi - Vietnam
- Material: 100% insulating natural rubber
- Color: Red brown
- Dimensions: 1m x 1m x 8mm thick
- Voltage used: 35,000V AC
- Test voltage: 35,000V AC / 1 minute
- Leakage current ≤ 20 mA
- Each product comes with a factory inspection card
0 ₫ 0.0 VND
VICADI 35KV insulating mat
TCD35KV / Vicadi - Vietnam
- Material: 100% insulating natural rubber
- Color: Red brown
- Thickness: 8mm
- Dimensions: 1mx0,65m ; 1mx1m ; 1mx2m
- Voltage used: 35,000V AC
- Test voltage: 35,000V AC / 1 minute
- Leakage current ≤ 20 mA
- Each product comes with a factory inspection card
0 ₫ 0.0 VND
VICADI 22KV insulating mat (1m x 0.65m)
TCD22KV-0.65x1 / Vicadi - Vietnam
- Material: 100% insulating natural rubber
- Color: Red brown
- Dimensions: 0.65m x 1m x 7mm thick
- Voltage used: 22,000V AC
- Test voltage: 22,000V AC / 1 minute
- Leakage current ≤ 20 mA
- Each product comes with a factory inspection card
(There are other sizes 1m x required length)
0 ₫ 0.0 VND
VICADI 22KV insulating mat (1m x 1m)
TCD22KV-1x1 / Vicadi - Vietnam
- Material: 100% insulating natural rubber
- Color: Red brown
- Dimensions: 1m x 1m x 7mm thick
- Voltage used: 22,000V AC
- Test voltage: 22,000V AC / 1 minute
- Leakage current ≤ 20 mA
- Each product comes with a factory inspection card (Other sizes are 1m x required length)
0 ₫ 0.0 VND
VICADI 10KV insulating mat (1m x 0.65m)
TCD10KV / Vicadi - Vietnam*
- Material: 100% natural insulating rubber
- Color: Reddish brown
- Thickness: 6mm
- Dimensions: 1x0.65m; 1x1m; 1x2m; 1x5m; 1x10m
- Operating voltage: 10,000V AC
- Testing voltage: 20,000V AC / 1 minute
- Leakage current ≤ 20 mA
- Each product comes with a factory inspection certificate
0 ₫ 0.0 VND
Insulating mat VICADI 10KV (1m x 1m)
TCD10KV-1x1 / Vicadi - Vietnam*
- Material: 100% insulating natural rubber
- Color: Red brown
- Dimensions: 1m x 1m x 6mm thick
- Voltage used: 10,000V AC
- Test voltage: 20,000V AC / 1 minute
- Leakage current ≤ 20 mA
- Each product comes with a factory inspection card
0 ₫ 0.0 VND
Sofamel 50kV insulating mat SP-1010/4
Class 4 insulating carpet / Sofamel - Spain
- Material: natural rubber
- Sock breaking voltage: 50,000V
- Size: 1.0x1.0 m
- Thickness: 4.5 mm
- Weight: ~7.8kg
- Standard: IEC 60243-1
0 ₫ 0.0 VND
The grounding pole withdrew Hasting 81-814
Hasting 81-814/ Mỹ
- Chiều dài: 2.43m
- Chiều dài hoạt động: 2.44m - 3.05m - 3.67m - 4.27m
- Trọng lượng: 3.5kg
0 ₫ 0.0 VND
The grounding pole withdraws Hasting 81-811
Hastings 81-811 / USA
- Length: 2.44m
- Operating length: 2.44m - 2.89m - 3.35m - 3.8m
- Weight: 3.3kg
0 ₫ 0.0 VND
Hasting 8108 external control grounding pole 2.59m
Hastings 8108 / USA
- Length: 2.59m
- Weight: 2.95kg
0 ₫ 0.0 VND
Grounding pole 3.84m 3.2kg Hasting 8212
8212/ Hastings - USA
- Length: 3.8m
- Weight: 3.2kg
0 ₫ 0.0 VND
Grounding pole 3.2m 2.88kg Hasting 8210
8210/ Hastings - USA
- Length: 3.2m
- Weight: 2.9kg
0 ₫ 0.0 VND
Grounding pole 2m 2.2kg Hasting 8206
8206 / Hastings - USA
- Length: 2m
- Weight: 2.2kg
0 ₫ 0.0 VND
Grounding pole 2.59m 2.6kg Hasting 8208
8208 / Hastings - USA
- Length: 2.6m
- Weight: 2.6kg
0 ₫ 0.0 VND
Hasting S-225 operating pole
S-225 / Hastings - USA
- Maximum length: 5.18mm - 6.4mm - 7.77m
- Shortened length: 1.5m
- Diameter: 55.5mm
- Weight: 3.2kg
Designed for safe long-range electrical work. Constructed with electrical grade reinforced fiberglass, for greater durability and high insulating properties.
0 ₫ 0.0 VND
Hasting S-220 operating pole
S-220 / Hasting - USA
- Maximum length: 5.18-6m
- Shortened length: 1.5m
- Diameter: 47mm
- Weight: 2.5kg
Designed for safe long-range electrical work. Constructed with electrical grade reinforced fiberglass, for greater durability and high insulating properties.